Occupant load by floor and space per IBC Table 1004.5. Add floors and spaces, select function, enter area. Fixed seating uses actual seat count.
← Back to Tools
Revit Text Output
Occupant load factors per IBC 2021 Table 1004.5. Function of space determines the occupant load factor — not the use group classification. Gross area includes corridors, stairs, restrooms, and mechanical rooms. Net area excludes non-occupiable spaces. For fixed seating, count actual seats per §1004.6; benches without dividing arms at 18 in. per person. The building official may establish a factor for unlisted functions based on the closest listed function. Green Stories LLC is a building design and consulting firm. All projects requiring a licensed architect are completed in collaboration with registered design professionals.